PRODUCT

HOME / RDS

RESPIRABLE DUST SAMPLER

RESPIRABLE DUST SAMPLER (PMI 410 NL)

Reference Standard : Meet requirements given in Bis 5182 (Part - 23) 2006


Flow Rate : 0.9 - 1.4 m3 /min free flow


Suction Pump : Low maintenance Brushless, Belt-less & Noise- less Turbine Blower where impellor is directly mounted on motor


Particle size : Particles of 10 microns & below collected on Filter Paper. Particles bigger than 10 microns collected in a separate sampling cup fitted Under the cyclone


Sampling Time : Upto 28 hours (maximum)


Automatic Sampling : 24 hrs programmable timer to automatically shut off the system after pre set time interval


Power Requirement : Nominal 220 V, Single Phase, 50Hz AC mains supply


Size & Weight : 960 mm x 440 mm x 350 mm, Approx 40 kg

OVERVIEW:-

DROP Enviro Engineers & Service made Respirable dust sampler ,PMI-410 NL sampler uses an improved cyclone (with sharper cutoff) to separate the coarser particles (>10 microns) from the air stream before filtering it on the 0.5 micron pore size filter allowing measurement of both TSP and Respirable fraction of suspended Particulate Matter (SPM).

our customers demand that high noise level is one main bottleneck for monitoring ambient air quality around schools, hospitals, libraries, institutional areas, wildlife sanctuaries and other noise sensitive areas. To moot this application specific requirement, we have, introduced PMI-410 NL which incorporates a noiseless brushless & Belt-less continuous duty Turbine blower.

SPECIAL-FEATURES

  • Brushless & Belt-less almost maintenance free & zero consumable Noiseless* Turbine Blower

  • Due to brushless motor, equipment downtime and ‘maintenance efforts are also considerably reduced. Modular design for Eazy operation

  • Sturdy Aluminium cabinate with all Stainless steel Hordware Design to run continuously 24 hr or more